{"product_id":"thql1120af2-general-electric-20-amp-1-pole-240-v-circuit-breaker","title":"THQL1120AF2 - General Electric - 20 Amp 1 Pole 240 V Circuit Breaker","description":"\u003ch2\u003eTHQL1120AF2 - General Electric - 20 Amp 1 Pole 240 V Circuit Breaker \u003c\/h2\u003e\n\u003cdiv class=\"summary-text-full\"\u003e\n\u003cp\u003e\u003cspan class=\"text-bold\"\u003eDescription: \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"description\"\u003eAFCI 20A CIRCUIT BREAKER\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-bold\"\u003eUPC:\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"upc\"\u003e783164652819\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"bigSummary\" id=\"summary\"\u003e\n\u003cdiv class=\"summary-text-full open\"\u003eArc fault breakers are designed to detect and prevent damage from arcing caused by damaged wire insulation or a frayed extension cord. All Q Line circuit breakers are one inch wide per pole, compact devices that feature: Quick-make \/ Quick-break mechanisms, common trip bars, and easy-to-spot trip indications to ensure safety and reliability. AF2 is called a Combination breaker as it protects against arcs in both parallel and series and meets current NEC standards. The TQHL1115 breaker Amps has 1 pole, an ampere rating of 15 A, an interrupting rating of 10 kAIC, and a voltage rating of 120\/240V.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 class=\"summary-text-full\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h3\u003e\n\u003ch3\u003eDescriptors\u003c\/h3\u003e\n\u003ctable width=\"100%\" class=\"product-list\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eCategory\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eArc Fault\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eProduct Line\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eQ-Line (Plug-In)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eGO Schedule\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eR9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" class=\"product-list\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eInterrupting Capacity Rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003e10 kAIC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eVoltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003e120\/240 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eNeutral Connection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003ePig Tail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eTrip Style\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eNon-Interchangeable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eFrame Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eQ-Line\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eAmperage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003e20 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eSystem Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003e120 Vac\u003cbr\u003e120\/240 Vac\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003ePoles\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eTrip Function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eLI\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eContinuous Current Rated\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eStandard\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003e120 Vac Interrupting Rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003e10 KAIC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003e120\/240 Vac Interrupting Rating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003e10 KAIC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eSuitable for Reverse Feed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eLong Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eFixed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eInstantaneous\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eFixed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eProtective Relays\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eNo\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eCurrent Metering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eNo\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eSpecial Markings\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eHACR\u003cbr\u003eSWD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eGSA Compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClassifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" class=\"product-list table-last\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"left-col\"\u003e\n\u003cp class=\"product-label mb-0 text-bold\"\u003eUL File #\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"right-col\"\u003e\n\u003cp class=\"product-description mb-0\"\u003eE11592\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003ePRODUCT DATASHEET\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"THQL1120AF2\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0711\/9873\/6657\/files\/THQL1120AF2.pdf?v=1754892744\"\u003eTHQL1120AF2 \u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51907022422289,"sku":"GETHQL1120AF2","price":56.98,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0711\/9873\/6657\/files\/GETHQL1120AF2_1.jpg?v=1772787194","url":"https:\/\/breakersnow.com\/products\/thql1120af2-general-electric-20-amp-1-pole-240-v-circuit-breaker","provider":"Breakers Now","version":"1.0","type":"link"}